Low Voltage Power Supply Configurator

Advanced Energy's Excelsys Low Voltage Power Supply Configurator helps you customize a power supply to meet your exact system requirements. Your new power supply can ship in one to two days directly from AE or distribution partners.

Input / Area Specifications

i Input Voltage (V)
The RMS value of the input AC voltage of your application. The input voltage range of CoolX600, UltiMod, Xsolo, and Xgen is 85 to 264 VAC.
i Application
Does your power supply need to meet the requirements of IEC60950 Standard/ITE? Or, the requirements of IEC60601-1 Medical? Or, Hi-Rel COTS requirements (MIL-STD-461F, MIL-STD- 810G and extreme temperature)?

Output Requirements

  Voltage (V) Current (A) Power Out (W)
Show More
Total Power Out Requirement

Additional Specifications

i Vtrim/Itrim/Remote Sense
CoolX, UltiMod, Xsolo, and Xgen output modules are available with various signaling options: remote voltage adjustment (Vtrim), remote current limiting (Itrim), and remote sense.
i Power Good Signal
Outputs can be provided with an opto-isolated Power Good signal to indicate the output voltage is within normal operation limits.
i Fan Air-Flow Direction
CoolX600 or XS500 do not require fan cooling. For UltiMod, XS1000, and Xgen standard air-flow direction is from the AC side to the DC-output side. UltiMod and Xgen offer optional reverse air-flow. This is ideal to expel warm air from the system and works well in conjunction with the integral fan cooling.

Some options are not available on MilSpec supply. Conformal coating and ruggedization are standard.

i Fan Noise
CoolX600 and XS500 have no fans. XS1000 has an integral, variable-speed, low noise fan. UltiMod and Xgen are available with multiple fan options. For acoustic sensitive applications, low-noise fans are available. However, this may also result in lower rated power outputs. See derating curves for more details.
i Ultra-Low Leakage Current
The standard leakage current of CoolX600, UltiMod, and Xsolo is 300 uA. Optional ultra-low leakage current of <150 uA is available. This is ideal for medical applications with two or more power supplies, or contain additional parts that contribute to system earth leakage.
i Conformal Coating
CoolX600, UltiMod, Xsolo, and Xgen are available with optional conformal coating for use in harsh environments and Hi-Rel MIL-COTS applications.
i Ruggedization
CoolX600, UltiMod, Xsolo, and Xgen are available with additional ruggedization for applications that are subject to extreme shock and vibration. When ruggedized, parts withstand shocks of up to 60 G and meet MIL-STD-810G standard for vibration.

Thank You

You may now view any resource on the Advanced Energy site. Click the button below to view your requested resource.

Thank You

You may now view any resource on the Advanced Energy site. Click the button below to view your requested resource.