- Products
- Gas Sensors
- Gas Monitors
- Innova 1512
Gas Sensors
Innova 1512
Highly Accurate, Stable, Quantitative, and Remotely Controllable Gas Monitoring System
Advanced Energy's Innova 1512 is based on the photoacoustic infrared spectroscopy and delivers superior sensitivity in a very compact form factor. Extremely versatile by design, the 1512 is capable of measuring almost any gas that absorbs infrared light.
- Leverages the unique strengths of the photoacoustic sensor technique
- User-friendly, stable, reliable, and highly accurate
- Extremely low-volume flushing possible
- Overview
- Technical Specs
- Documents
- Accessories
- Service & Support
- Distributors
Overview
Advanced Energy’s Innova® 1512 is a highly accurate, reliable, and stable quantitative gas monitoring system. Its measurement system, based on the photoacoustic infrared detection method, is capable of measuring almost any gas that absorbs infrared light.
Gas selectivity is achieved through the use of optical filters. By installing up to five filters, the 1512 can measure the concentration of up to five component gases and water vapor in any air sample. The detection limit is gas-dependent, but is typically in the ppb region. Accuracy of these measurements is ensured by the 1512’s ability to compensate for temperature and pressure fluctuations, water vapor interference, and interference from other gases known to be present.
Benefits
- Selectively measure a wide range of gases / vapors
- Ensure a maximum of only two calibrations a year
- Operate immediately with virtually no warm-up time necessary
- Easily calibrate, configure, and view / analyze data via PC
- Accurately compensate for temperature and pressure fluctuations, water vapor interference, and interference from other known gases
Features
- Linear response over a wide dynamic range
- Remote control capability via TCP/IP network interface protocol
- Expandable up to 24 locations with Innova 1409 Multipoint Sampler; the gas monitor can operate as the system controller for full standalone operation
- Includes BZ7002 calibration software
- Includes BZ7003 offline software to set up the gas monitor without connecting it to a PC and to download data stored in the gas monitor's internal memories
- Available in single gas, dual gas, and 5 gas configuration
-
Measurement Specifications
Detection Limit
Gas dependent, but typically in the ppb region; using the Gas Detection Limits Chart, the detection limit for a selected sample integration time (SIT) can be calculated
Dynamic Range
Typically four orders of magnitude (i.e., 10,000 times the detection limit at 5 SIT); using two span concentrations it can be expanded to five orders of magnitude
Repeatability
1% of measured value
Measured at 20°C, 1013 mbar, and relative humidity (RH): 60%; a concentration of 100x detection limit (5s SIT) was used in determining these specificationsInterference
The 1512 automatically compensates for temperature and pressure fluctuations in its analysis cell and can compensate for water vapor in the air sample; if an optical filter is installed to measure a known interferent, the 1512 can cross compensate for the interferent
Internal Data Storage Capacity
The total space available in display memory to store data ia 131072 measurement cycles; if a measurement cycle takes 15 sec, then the display Memory space will be sufficient for a 22-day monitoring task
-
Environmental Specifications
Operating Temperature
5 to 40°C (41 to 104°F)
Humidity
Maximum relative humidity: 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C
Enclosure
IP 20
H x W x D
195 x 443 x 244 mm (7.68 x 17.44 x 9.60 in)
Weight
11 kg (24.3 lb)
-
Pumping System Specifications
Pumping Rate
30 cm3/s (flushing sampling tube) and 5 cm3/s (flushing measurement chamber)
Air Volume Per Sample
Total Internal Volume
60 cm3 (of the measurement system)
-
Electrical and Communication Specifications
Power Ratings
~85 VA, 100 to 240 VAC ±10%, 50 to 60 Hz, Class 1
Alarm Relay Socket
For connection to one or two alarm relays (visual / audio)
Alarm levels for each gas are user-defined
System on / running status available
Maximum 25 VDC, maximum 100 mABack-Up Battery
3 V lithium battery, lifetime 5 years; this protects data stored in memory and powers the internal clock
Monitor Interface
Three interfaces: USB, Ethernet, and RS232, for data exchange and remote control of the instrument
Software Communication
Via USB, Ethernet, or RS232 interface
-
Safety and Standards Specifications
Safety
EN/IEC 61010-1 3rd edition
CAN/CSA C22.2 No. 61010-1-04
UL 61010-1 3rd editionEMC
EN 61326-1:2013: Electrical equipment for measurement, control and laboratory use – EMC requirements; Part 1: General requirements
Standards Compliance
CE-mark indicates compliance with: EMC Directive and Low Voltage Directive
NEMKO mark indicates compliance with: CSA and UL Standards -
Typical Applications
- Measurement of refrigerant emissions from mobile A/C systems
- Animal husbandry
- Soil science
- Fumigant monitoring
- Contaminated soil
- Ventilation performance
- Industrial hygiene-IAQ monitoring
- Waste anesthesia monitoring
- Biogas analysis
- Sordet gas filter testing
- Photocatalytic material testing
- Research and development
- SF6 leak testing
Specifications are subject to change without notice. Not all options and accessories are available for all models and configurations. Dimensions listed generally refer to standard configurations and module bodies only. Please confirm technical specifications and customizations with a sales representative. Advanced Energy is not responsible for errors or omissions.
Data Sheets
Brochures
Manuals
Application Notes
Helpful Links
Accessories
Documents & Support
View All Innova 1512 AccessoriesGlobal Support & Services
Maximize fab productivity and capital equipment ROI with world-class support through each product lifecycle stage — from startup to long-term operation. Our service offerings are based on more than three decades of precision power and applications expertise.
Applications Support & Consulting
Accelerate tool installations and process development programs, or address specific applications concerns with Advanced Energy's dedicated applications consultants and engineering staff. Benefit from on-site reviews, analyses, and consultations.
Warranties
Decrease variability in maintenance costs and provide additional cost protection. Advanced Energy offers whole-box extended warranties.
Product Support
Call
U.S.: +1 800 446 9167
Asia: +86 29 8874 1895
China: 400 8899 130
EMEA: +44 800 032 1546
U.K.: 08000 321 546
Email
Thin Film Support
Thermal Product Support
Other Technical Support
Find an AE Representative or Distributor
To find distributors and representatives who sell AE products in your area, select your location and vendor type (optional).